CONTEC CMS8500 Vital Signs Monitor

ZAR27,965.00

Product may vary slightly from image representation.
CMS8500 Patient Monitor The monitor boasts a plethora of functions suitable for clinical monitoring of adults, pediatrics, and neonates. Users have the ability to select parameter configurations tailored to specific requirements. Powered by 100V-240V~, 50Hz/60Hz, the monitor is equipped with a 14" color TFT LCD display presenting real-time data and waveforms. The device can simultaneously display ten-channel waveforms and complete monitoring parameters while offering an optional 48mm thermal recorder. Additionally, the monitor can be wirelessly or wiredly connected to a central monitoring system to form a network monitoring system. This apparatus can monitor vital parameters, including ECG, RESP, NIBP, SpO₂, and dual-channel TEMP, among others. The parameter measurement module, display, and recorder are integrated into a single, compact, and portable device. Furthermore, its replaceable internal battery brings a great deal of convenience for patient mobility. Function: 14" high-definition touch screen design, easy and convenient to operate, elegant and concise in appearance. Independent physiological and technical alarm function, convenient for medical staff to quickly know patient's condition. Adopt high-performance processor, stable, reliable and fast to process information. Patient information can be rapidly entered, patient type (adult/neonate/pediatric) can be quickly switched, meets the requirements of different departments. Abundant analysis functions: 23 arrhythmia, full-lead ST-segment and pacing analysis; multiple calculation functions (such as calculation of drug concentration, titration table, hemodynamics, ventilation, oxygenation, renal function, ). With the functions of waveform freezing, holographic waveform storage and review. Automatic data storage in case of power failure. Built-in large-capacity detachable lithium battery, ensures uninterrupted monitoring. Fanless design, ensures no noise and low power consumption during working. Connect to Central Monitoring System developed by our company by WiFi/Wired, convenient to transmit patient's real-time information by mode, be applied to clinical monitoring, avoids affecting patient's rest, one-button switching, reduces the workload of medical staff. Performance: ECG Leadtype: 3-lead: I, II, II 5-lead: l, II, Il, aVR, aVL, aVF, V 12-lead: l, ll, Il, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6 Gain: 5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV Scanspeed: 25mm/s, 12.5mm/s, 25mm/s, 50mm/s HR Measurement and alarm range: Adult: 15~300 bpm Pediatric/neonate: 15~350 bpm Resolution: 1 bpm Accuracy: ±1% or ±1bpm, whicheveris greater. ST-segmentdetection Measurement and alarm range: -2.0mV~+2.0 mV Accuracy: -0.8mV~+0.8mV: ±0.04mV or ±10%, whicheveris greater. Other range: unspecified Arrhythmiaanalysis: 23 kinds Pacemaker: yes RESP Measurementmode: impedance Respirationrate: Measurement range: 0 rpm~150 rpm Resolution: 1 rpm Accuracy: 7~150 rpm, ±2rpm or±2%, whicheveris greater; 0~6 rpm, unspecified Apneaalarm: 10~60s. Scanspeed: 25mm/s, 12.5 mm/s, 25mm/s, 50mm/s. NIBP Measurementmode: Oscillometry Workingmode: Manual/AUTO/Continuous/Order Measurementinterval in AUTO mode: 1 min, 2 min, 5 min, 3 min, 5 min, 10 min, 15 min, 20min, 30min, 1h, 1.5h, 2h, 3h, 4h, 8h Measurement period in Continuous mode: 5 minutes Staticpressure Measurement range: 0mmHg~300 mmHg (0.0kPa~40kPa) Resolution: 1mmHg Cuffpressure accuracy: ±3mmHg Measurementaccuracy: Maximal mean deviation: ±5 mmHg Maximal standard deviation: 8 mmHg Over-pressureprotection: Adult mode: 297±3mmHg Pediatric mode: 260±3 mmHg Neonatal mode: 147±3mmHg SpO₂ Measurementrange: 0%~100 % Resolution: 1% Accuracy: 70%~100%, ±2%;0%~69%, unspecified PR Measurement and alarm range: 25~250 bpm Accuracy: ±2 bpm or±2%, whicheveris greater. TEMP Channel: dual-channel Measurementrange: 0~50℃ Resolution: 1℃ Accuracy: ±0.1℃ CO₂ Measurement mode: mainstream or sidestream CO₂ measurementrange: 0~150 mmHg Accuracy: 0~40mmHg: ±2mmHg; 41~70mmHg: ±5%; 71~100mmHg: ±8%; 101~150mmHg: ±10% AwRR measurement range: Sidestream: 2~120 rpm; Mainstream: 2~150 rpm. AwRRaccuracy: ±1rpm Apneaalarm: yes IBP Channel: 2-channel(Expandable 4-channel) Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and alarm range: -50~300 mmHg. Resolution: 1mmHg. Accuracy: ±2%or 1 mmHg, whicheveris greater. Power supply: 100V-240V~50Hz/60 Hz. Safety class: classl, defibrillation-proof type CF applied part. Waterproof degree: IPX2.