CONTEC TS15 Patient Monitor

ZAR76,965.00

Product may vary slightly from image representation.
The monitor is applicable for clinical monitoring in operating room, postoperative observation room, ICU/CCU ward, emergency room, etc. of adult, pediatric and neonate. The patient's vital parameters (ECG (including ST-segment measurement and arrhythmia analysis), RESP, SpO2, PR, NIBP, TEMP, IBP and CO2, etc.) can be monitored. Monitored information can be displayed, reviewed, printed and stored.. 2 Function 15.6" high-definition touch screen design, easy and convenient to operate, elegant and concise in appearance. Independent physiological and technical alarm function, convenient for medical staff to quickly know patient’s condition. Luminous “ON / OFF” button design, convenient to operate at night. Modular design: the modules can be configured and combined flexibly and conveniently, expanded and upgraded at any time, meets the monitoring requirements of different departments on different parameters. Support dynamic hot-plugging parameter module: no need to restart the device, plug-and-play, change the monitoring parameters at any time as clinical requirements. Adopt high-performance processor, stable, reliable and fast to process information. Patient information can be rapidly entered, patient type (adult / neonate / pediatric) can be quickly switched, meets the requirements of different departments. Abundant analysis functions: 23 arrhythmia, full-lead ST-segment and pacing analysis; multiple calculation functions (such as calculation of drug concentration, titration table, hemodynamics, ventilation, oxygenation, renal function, etc.). With the functions of waveform freezing, holographic waveform storage and review. Automatic data storage in case of power failure; optional built-in memory card, achieves large-capacity data storage. With HDMI expansion interface, the display screen can be connected according to clinical requirements. Built-in large-capacity detachable lithium battery, ensures uninterrupted monitoring. Fanless design, ensures no noise and low power consumption during working. 3-channel built-in recorder used to print real-time waveform is optional. Connect to Central Monitoring System developed by our company by WiFi / Wired, convenient to transmit patient’s real-time data. Standby mode, be applied to ICU, avoids affecting patient’s rest, one-button switching, reduces the workload of medical staff. 3 Performance ECG Lead type: 3-lead: I, II, III 5-lead: I, II, III, aVR, aVL, aVF, V Gain: 5mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV Scan speed: 5 mm/s, 25 mm/s, 50 mm/s HR Measurement and alarm range: Adult: 15 ~ 300 bpm Pediatric/neonate: 15 ~ 350 bpm Resolution: 1 bpm Accuracy: ± 1 % or ± 1 bpm, whichever is greater ST-segment detection Measurement and alarm range: - 2.0 mV ~ + 2.0 mV Accuracy: - 0.8 mV ~ + 0.8 mV: ± 0.04 mV or ± 10 %, whichever is greater Other range: unspecified Arrhythmia analysis: 23 kinds Pacemaker: yes RESP Measurement mode: R-F(RA-LL) impedance Respiration rate: Measurement range: Adult: 0 rpm ~ 120 rpm Pediatric/neonate: 0 rpm ~ 150 rpm Resolution: 1 rpm Accuracy: 7 ~ 150 rpm, ± 2 rpm or ± 2 %, whichever is greater; 0 ~ 6 rpm, unspecified Apnea alarm:10 ~ 120 s, not alarm Scan speed: 25 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s NIBP Measurement mode: Oscillometry Working mode: Manual/AUTO/Continuous Measurement interval in AUTO mode: 1min, 2 min, 5 min, 3 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1 h, 1.5 h, 2 h, 3 h, 4 h, 8 h Measurementperiod in Continuous mode: 5 minutes Measurement and alarm range: 10~ 270 mmHg Resolution: 1mmHg Cuff pressure accuracy:± 3 mmHg Measurement accuracy: Maximal mean deviation: ± 5 mmHg Maximal standard deviation: 8 mmHg Over-pressure protection: Adult mode: 297 ± 3 mmHg Pediatric mode: 240 ± 3 mmHg Neonatal mode: 147 ± 3 mmHg CONTEC SpO2 Measurement range: 0% ~ 100 % Resolution: 1% Accuracy: 70% ~ 100 %, ± 2 %; 0 % ~ 69 %, unspecified PR Measurement and alarm range: 25 ~ 250 bpm Accuracy: ± 2 bpm or ± 2 %, whichever is greater NellcorSpO2 Measurement range: 1% ~ 100 % Measurement accuracy: 70% ~ 100 %: ± 2 % (adult / pediatric) 70 % ~ 100 %: ± 3 % (neonate) 0 % ~ 69 %: unspecified NellcorPR Measurement range: 20 ~ 300 bpm; Measurement accuracy: 20 ~ 250 bpm, ±3 bpm; 251 ~ 300 bpm: unspecified; Upper limit of alarm: upper limit - 2 ~ 300 bpm; Lower limit of alarm: 20 bpm ~ lower limit + 2 bpm MasimoSpO2 Measurement range: 1% ~ 100 % Measurement accuracy: 70 % ~ 100 %: ± 2 % (adult / pediatric, under conditions of no motion), ± 3 % (under conditions of motion) 70 % ~ 100 %: ± 3 % (neonate, under conditions of no motion) 1 % ~ 69 %: unspecified MasimoPR Measurement range: 25 ~ 240 bpm Measurement accuracy: ± 3 bpm (under conditions of no motion), ± 5 bpm (under conditions of motion) Upper limit of alarm: upper limit - 2 ~ 240 bpm Lower limit of alarm: 25bpm ~ lower limit + 2 bpm TEMP Channel: dual-channel Measurement range: 0~ 50 ℃ Resolution: 1℃ Accuracy: ±1 ℃ CO2 Measurement mode: mainstream or sidestream CO2measurement range: 0 ~ 150 mmHg CO2resolution: 1 mmHg: 0 ~ 69 mmHg 0.25 mmHg: 70 ~ 150 mmHg Accuracy: 0 ~ 40 mmHg: ± 2 mmHg 41 ~ 70 mmHg: ± 5 % 71 ~ 100 mmHg: ± 8 % 101 ~ 150 mmHg: ± 10 % AwRRmeasurement range: Sidestream: 2 ~ 120 rpm Mainstream: 2 ~ 150 rpm AwRRaccuracy: ± 1 rpm Apnea alarm:yes IBP Channel: 4-channel Label: ART, PA,CVP, RAP, LAP, ICP, P1, P2 Measurement and alarm range: -50~ 300 mmHg Resolution: 1 mmHg Accuracy: ±2 % or 1 mmHg, whichever is greater Power supply: 100~ 240 V ~ 50/60 Hz Safety class: class I, defibrillation-proof type CF applied part Waterproof degree: IPX2